PremiumConstruction · Electrical

Circuit load and breaker sizing

Load current, breaker size with the 125% continuous rule and a matching copper conductor.

Get this tool with its role plan

This is a premium tool. It comes with its role's plan: sign in, then add the role in Billing.

Comes with the electrician plan: every tool for the role, from $10.20 a month at the launch price.

  • Your own numbers, worked out as often as you like
  • The full circuit sheet you can print or save to My work
  • 3 cited sources, linked, with the checks to make
  • Every other tool for the same role, in the same plan
  • A plain-words read of your result (a fuller AI read with the Bifrost AI add-on)

Included in these role plans

ElectricianElectrical engineerEstimator

Example result · fictional numbers

What you get: circuit sheet

Worked out by this tool from its default inputs. Its role plan lets you run your own numbers, print the sheet and save it.

40 A 2-pole breaker, 8 AWG copper, 10 AWG ground, 1/2 in EMT, 1.5% drop

Load current
30.0 A
Required breaker rating
37.5 A
Standard breaker
40 A
Copper conductor (75 °C)
8 AWG THHN
Breaker loading
75% of rating

Branch circuit

Breaker
40 A 2-pole (next standard size at or above 37.5 A, 125% of the continuous load)
Conductors
8 AWG copper THHN/THWN-2
Ampacity after adjustment
55 A at 90 °C × 100% (2 current-carrying conductors) × 1.00 (ambient) = 55.0 A; carries 30.0 A and is protected by the 40 A breaker
Terminal check
50 A at 75 °C, at least the 40 A breaker (terminals are rated 75 °C)
Equipment grounding conductor
10 AWG copper for a 40 A breaker (Table 250.122); size it up in proportion if you upsize the hots for voltage drop
Conductors in the run
2 hots, 1 ground (3 wires)

Also on the sheet

  • Conduit and voltage drop · 5 lines, starting with “EMT for this circuit”
  • Panel schedule line · 4 lines, starting with “Circuit”

The plain-words read of this example

A 7,200 W load at 240 V draws 30.0 A, so it takes a 40 A 2-pole breaker after the 125% continuous-load rule. 8 AWG copper is the smallest wire that fits: 55.0 A after adjusting for 2 conductors and the ambient. It needs a 10 AWG copper ground and fits 1/2 in EMT. Over 75 ft the drop is 1.5%, inside the 3% the NEC recommends. Check the nameplate first: motors, HVAC and welders follow their own articles, and the inspector has the last word.

3 cited sources

  • NFPA 70, National Electrical Code (NEC) (National Fire Protection Association)
  • NEC Chapter 9 (Tables 1, 4, 5 and 8) and Informative Annex C (NFPA free access (read-only, free account))
  • OSHA 29 CFR 1926.404, Wiring design and protection (construction sites) (U.S. Occupational Safety and Health Administration)

Plus 6 step-by-step checks, a print layout and a link that reopens it with your numbers.

Sign in to pin this tool to My work.

Norventus

Applied Intelligence, three ways.

One way of thinking, built for three different jobs. Here is how they compare.

  • Applied Intelligence

    Watch TowerFor Business

    Who it is for
    Leaders and operators of an organization.
    What you get
    Your team, goals and KPIs, assets on one map and a work tracker, set up with you in the Watch Tower Console in four weeks, then reviewed with you every week.
    How to start
    Start from your goal. The demo is free.
    Visit Watch Tower
  • Applied Intelligence

    BeaconFor Professionals

    Who it is for
    One professional and where their career goes next.
    What you get
    A personal career console: news for your role, certifications, a pay-target planner, lessons and projects.
    How to start
    3 days free. No card needed to start.
    Visit Beacon
  • Applied Intelligence

    ForgeFor your Work

    Who it is for
    The people who do the work, on site (Crew) or at a desk (Labs).
    What you get
    Small, clear tools for everyday jobs: calculators, quick references and checklists.
    How to start
    Many tools are free. No account needed.
    You are here